BYGYR - ZINC CHROMATE PRIMERS, 960

  • MSDS: BYGYR
  • Manufacturer: RUST OLEUM CORP
  • Product Name: ZINC CHROMATE PRIMERS, 960
  • National Stock Number: 8010-00-835-0878
Product Identification

Product ID:ZINC CHROMATE PRIMERS, 960
MSDS Date:11/15/1985
FSC:8010
NIIN:00-835-0878
MSDS Number: BYGYR

Responsible Party
RUST-OLEUM CORP
11 HAWTHORN PKWY
VERNON HILLS, IL 60061
US

Emergency Phone: 312-367-7700

Info Phone: 312-367-7700

Cage: 08882

Contractor
RUST-OLEUM CORP
VERNON HILLS, IL 60061-1583 US

Telephone: 847-367-7700

Cage: 08882

Ingredients

2

CAS: 8030-30-6

RTECS: DE3030000

Fraction By Weight: 35%

OSHA PEL N/K

ACGIH TLV: 500 PPM (MFR)


CHROMIC ACID, ZINC SALT, BASIC; (ZINC CHROMATES)

CAS: 50922-29-7

RTECS: GB3295000

Fraction By Weight: 10%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION: ANESTHETIC,
IRRITATION OF THE RESPIRATORY TRACT OR ACUTE NERVOUS SYSTEM
DEPRESSION CHARACTERIZED BY HEADACHE, DIZZINESS, STAGGERING,
CONFUSION, UNCONSCIOUSNESS OR COMA. SKIN/EYE CON TACT: PRIMARY
IRRITANT. CHRONIC: REPORTS HAVE SHOWN REPEATED AND PROLONGED
OCCUPATIONAL OVEREXPOSURE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:ZINC CHROMATE: IARC GROUP 1, SUP 7, P
165, 1987; KNOWN CARCINOGEN, NTP 7TH ANNUAL REPORT ON CARCINOGENS,
1994.
Effects of Overexposure:HLTH HAZ: TO SOLVENTS WITH PERMANENT BRAIN AND
NERVOUS SYSTEM DAMAGE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST: CALL MD IMMEDIATELY . INHAL: REMOVE FROM EXPOSURE,
RESTORE BREATHING AND NOTIFY MD. EYES: FLUSH IMMEDIATELY WITH LARGE
AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. NOTIFY MD. SKIN: WASH AFF
ECTED AREA WITH SOAP AND WATER, REMOVE CONTAMINATED CLOTHING.

Fire Fighting

Flash Point Method:TCC
Flash Point:104F,40C
Extinguishing Media:NFPA CLASS B EXTINGUISHERS (CARBON DIOXIDE, DRY
CHEMICAL OR FOAM).
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
WATER SPRAY MAY BE INEFTIVE, BUT MAY BE USED TO COOL CLSD CNTNRS TO
PVNT PRESS BUILDUP & POSS (SUPDAT)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPK & OPEN FLAME. CLSD CNTNRS MAY EXPLDOE WHEN
EXPOSED TO EXTREME HEAT. DO NOT APPLY TO HOT SURFACES.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION, VENTILATE AREA
AND REMOVE WITH INERT ABSORBENT AND NON-SPARKING TOOLS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 120F. STORE LARGE
QUANTITIES IN BUILDINGS DESIGNED & PROTECTED FOR STORAGE OF NFPA
CLASS II FLAMMABLE LIQUIDS.
Other Precautions:CONTAINERS SHOULD BE GROUNDED WHEN POURING. DO NOT
TAKE INTERNALLY. EMPTY CONTAINERS MAY BE HAZARDOUS.

Exposure Controls

Respiratory Protection:USE A NIOSH/MSHA APPROVED MECHANICAL FILTER
RESPIRATOR TO REMOVE SOLID AIR BORNE PARTICLES OF OVERSPRAY DURING
SPRAY APPLICATION. IN CONFINED AREAS USE NIOSH/MSHA APPROVED AIR
LINE TYPE RESPIRATORS OR HOODS.
Ventilation:PROVIDE GEN DILUTION OR LOC EXHST VENTILATION IN VOL &
PATTERN TO KEEP TLV OF MOST HAZ INGRED BELOW ACCEPTABLE LIMIT.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC: AUTOIGNITION/EXPLOSION. IF WATER IS USED, FOG NOZZLES
ARE PREFERRED.

Chemical Properties

Boiling Pt:B.P. Text:>313F,>156C
Vapor Pres:SEE ING 1
Vapor Density:HVR/AIR
Spec Gravity:1.26-1.44
Evaporation Rate & Reference:SLOWER (ETHER=1)
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:49-56

Stability

Stability Indicator/Materials to Avoid:YES
INCOMPATIBLE WITH STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY OPEN FLAME - CARBON MONOXIDE AND
CARBON DIOXIDE.

Disposal

Waste Disposal Methods:DISPOSE OF ACCORDING TO LOCAL, STATE AND FEDERAL
REGULATIONS. DO NOT INCINERATE CLOSED CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.